Swapping a drive in a Linux software RAID1 (mdadm) is routine, but a few NVMe-specific details make it easy to pull the wrong disk. This note walks through identifying the array, removing the drive, adding the replacement and estimating rebuild time.

1. Identify the array and its members

cat /proc/mdstat

Example output:

md1 : active raid1 nvme1n1[1] nvme0n1[0]
      937560384 blocks super 1.2 [2/2] [UU]
      bitmap: 2/7 pages [8KB], 65536KB chunk

From this:

For more detail, including each member’s state:

sudo mdadm --detail /dev/md1

If a disk holds partitions belonging to several arrays (for example /boot, swap and /), check each partition with sudo mdadm --examine /dev/nvme1n1p1 and repeat the removal steps for every array.

2. Confirm which physical drive to remove

NVMe numbering (nvme0, nvme1) does not necessarily follow slot order, so always match by serial number:

lsblk -o NAME,SIZE,TYPE,MOUNTPOINT,MODEL,SERIAL
sudo nvme list                  # needs nvme-cli
sudo smartctl -a /dev/nvme1n1   # health and serial number

Compare the serial number with the label on the physical drive before pulling it. If both members show [UU], use SMART data to decide which disk is actually failing.

3. Fail and remove the drive

sudo mdadm /dev/md1 --fail /dev/nvme1n1 --remove /dev/nvme1n1

Verify that the array is now degraded but running:

cat /proc/mdstat    # expect [2/1] [U_] or [_U]

Before shutting down or pulling the disk, make sure the remaining disk can boot the system, for example by confirming the bootloader is installed on it.

If the drive is hot-swappable and you are not powering the server off, detach it from the kernel before pulling it. This is the NVMe equivalent of echo 1 > /sys/block/sdX/device/delete for SATA/SAS disks. NVMe has no delete attribute on the block device, so remove the underlying PCI device instead:

echo 1 | sudo tee /sys/block/nvme1n1/device/device/remove

Skip this step if you shut the server down to replace the drive.

4. Add the replacement drive

After installing the new drive, check its device name with lsblk. If you hot-swapped the drive and removed the PCI device in the previous step, rescan the PCI bus first so the kernel detects the new one:

echo 1 | sudo tee /sys/bus/pci/rescan

Then add it:

sudo mdadm /dev/md1 --add /dev/nvme1n1

If the array members are partitions, partition the new disk to match the surviving one first.

5. Rebuild time

mdadm works below the filesystem and does not know which blocks hold data. A new disk always gets a full copy, so a half-empty 1 TB array takes as long to rebuild as a full one.

The usual bottleneck is the kernel’s resync throttle, not the NVMe drive. The default speed_limit_max is about 200 MB/s:

Setting Approx. time for ~937 GB
Default limit (~200 MB/s) ~1–1.5 hours
Raised limit, fast NVMe (1–3 GB/s) ~5–15 minutes
Raised limit, QLC drive after cache fills ~20–30 minutes
Busy server (falls toward speed_limit_min) Much longer

To speed up the rebuild:

sudo sysctl -w dev.raid.speed_limit_max=2000000
sudo sysctl -w dev.raid.speed_limit_min=500000

Higher limits put more I/O load on the server, so raise speed_limit_min cautiously on production systems. The values reset at reboot.

Watch progress with:

watch -n 5 cat /proc/mdstat

Re-adding the same disk

If a disk was removed only temporarily and is put back unchanged, the write-intent bitmap lets md resync just the regions that changed:

sudo mdadm /dev/md1 --re-add /dev/nvme1n1

This can finish in seconds or minutes. It does not apply to a new replacement disk.